Vibration Measurement on the Kassel Wire Bridge
The Kassel Wire Bridge is a suspension bridge that was built in 1997 based on a historical model, using the existing piers, with a steel structure and deck slabs made of precast reinforced concrete. Shortly after its construction, the bridge was equipped with a vibration damper.
To assess the vibration damper’s performance after approximately 25 years of operation, the Department of Structural Engineering at the University of Kassel was commissioned to conduct vibration measurements, which took place in April of this year.
First, so-called free-damping tests were conducted. In these tests, the bridge was left to its own devices after a force impulse was applied, and the bridge’s slowly decaying, free vibration was measured. Using a Fast Fourier Transform, the power spectra of the vibrations were determined, which in turn allowed the relevant natural frequencies to be calculated.
In the second step, the bridge’s vibration response was measured under externally applied force excitation. The external force excitation consisted of a group of people walking in sync across the entire length of the bridge (see video below). To achieve the greatest possible vibration amplitudes, the walking frequency of the group had to correspond exactly to one of the bridge’s natural frequencies. These experiments were repeated at various natural frequencies, both with the vibration damper fixed and with it free to move.
During each measurement, the vertical and horizontal accelerations as well as the relative displacement between the bridge and the vibration damper were recorded.