Student Projects
The Department of Building Physics currently offers the following master's theses, bachelor's theses, term papers, and project papers:
Durability of Flat Roof Structures – An Investigation of Typical Construction Defects and Their Impact on Convective Moisture Transport
Background and Problem Statement
Due to the increased installation of PV systems and the “solar roof mandate” for new non-residential buildings starting in 2027, the load behavior of unused flat roofs is becoming a key focus for structural engineers. PV systems generate additional static and dynamic loads that must be taken into account in the design of flat roofs. Parameters for describing these new requirements must be determined and incorporated into the standardization of new component functions.
Scientific publications frequently show a decline in the compressive strength of mineral wool insulation in flat roofs due to water absorption. Convection resulting from leaks in the building’s thermal envelope is considered a common cause of water absorption. Buildings constructed with trapezoidal steel sheet roofing, whose roofs were opened after decades of service, generally show no damage to the insulation layer when the airtightness layer and exterior waterproofing are intact; the measured compressive strength of the insulation layer is at a level sufficient to allow access for maintenance purposes and the installation of PV systems.
The objective of the master’s thesis described below is, in the first phase, to research and document typical construction defects in the installation of flat roof waterproofing. In a second phase, these construction defects will be replicated in real-scale laboratory tests, and their convective behavior will be recorded and evaluated.
Objective of the Master’s Thesis
The objective of this master’s thesis is to systematically identify typical construction defects in the installation of flat roof structures and to experimentally investigate their influence on convective air and moisture transport.
To this end, relevant damage mechanisms and common construction errors will first be researched and evaluated based on scientific publications, technical codes, and documented damage cases.
Based on these investigations, selected construction defects will be specifically replicated on a full-scale flat-roof test setup in the laboratory. Using appropriate measurement methods, the flow and convection behavior of the examined defects will be recorded and quantitatively evaluated.
The study aims to help identify critical construction details and derive requirements for flat roof structures that remain functional over the long term.
Work Tasks
1. Literature review and analysis of the state of the art
- Research into scientific publications on moisture absorption, moisture transport, and the durability of flat roof structures.
- Description of the relationship between moisture content and the mechanical properties of thermal insulation materials, particularly compressive strength.
- Analysis of relevant technical codes and standards regarding airtightness and waterproofing of flat roofs.
- Research and systematic documentation of typical design and construction errors.
- Evaluation of damage mechanisms caused by air flow and convective moisture transport.
2. Selection and Evaluation of Relevant Construction Defects
- Classification of typical defects in airtightness and waterproofing layers.
- Identification of particularly critical connection details, penetrations, and component interfaces.
- Selection of representative construction defects for experimental investigations.
- Development of a research concept incorporating the external technical expertise of the specialists involved in the project.
3. Experimental investigations on a full-scale test setup
- Development of a suitable measurement concept for recording airflow and, where applicable, convective moisture transport.
- Documentation of measurements at selected defective locations on a full-scale flat-roof structure in the laboratory.
- Investigation of the influence of the type, location, and severity of the defects on flow behavior.
4. Analysis and scientific evaluation
- Quantitative analysis of the experimentally determined measurement data.
- Comparison of the flow behavior associated with the various defects.
- Assessment of the construction defects examined with regard to their potential for convective moisture transport.
- Discussion of the effects on the functionality and durability of flat roof structures.
- Derivation of recommendations for avoiding critical construction defects and for the metrological verification of airtightness.
Expected Results
As part of this master’s thesis, a systematic overview of relevant construction defects in flat roof structures will be developed. The experimental investigations are intended to provide quantitative insights into the airflow behavior of selected defects and to highlight their significance for potential convective moisture transport.
The results are intended to form a basis for evaluating the durability of flat roof structures and for the further development of suitable construction and testing methods.
A co-authored publication of selected results in a relevant scientific journal is planned.
Contact:
Prof. Dr.-Ing. Peggy Freudenberg; peggy.freudenberg[at]uni-kassel[dot]de
Dipl.-Ing. Rolf Gross; rolf.gross[at]uni-kassel[dot]de