Air Tightness Testing of Buildings (Blower Door Tests)

Scope of Application

  • Air Tightness Testing of the Building Envelope
  • EnEV Compliance Testing
  • Leak Detection
  • Preparing renovation measures and, if necessary, reviewing measures already taken
  • Examining the airtightness of individual building components or building areas
  • Inspection of ventilation systems
  • In conjunction with thermography, visual documentation of leaks
  • ...

High measurement accuracy thanks to computer-assisted data acquisition. Precision differential pressure sensors with an accuracy of 0.25% of full scale (standard devices: 2–5%) are used.

Measurement of entire buildings in accordance with DIN EN 13829 or according to specified criteria.

Image: Uni-Kassel

Examples of Use

Quantification of individual building areas (e.g., individual rooms):

  • Guardzone measurements for the exterior walls of the areas of interest
  • Deduction measurements for exterior and interior walls of interest
  • "Opening a Door" and "Adding a Hole" measurement methods when speed and simplicity are needed or when other methods fail (exterior and interior walls)

Leak detection and documentation, available upon request, including

  • using smoke tests, leak detection from the inside and outside
  • in conjunction with thermography

Technical Specifications

Measurement range

  • Standard: up to 10,000 m³/h and a 60 Pa pressure differential between indoors and outdoors
  • Extended up to 30,000 m³/h and a pressure difference of 60 Pa between indoors and outdoors