Air Tightness Testing of Buildings (Blower Door Tests)
Scope of Application
- Air Tightness Testing of the Building Envelope
- EnEV Compliance Testing
- Leak Detection
- Preparing renovation measures and, if necessary, reviewing measures already taken
- Examining the airtightness of individual building components or building areas
- Inspection of ventilation systems
- In conjunction with thermography, visual documentation of leaks
- ...
High measurement accuracy thanks to computer-assisted data acquisition. Precision differential pressure sensors with an accuracy of 0.25% of full scale (standard devices: 2–5%) are used.
Measurement of entire buildings in accordance with DIN EN 13829 or according to specified criteria.
Examples of Use
Quantification of individual building areas (e.g., individual rooms):
- Guardzone measurements for the exterior walls of the areas of interest
- Deduction measurements for exterior and interior walls of interest
- "Opening a Door" and "Adding a Hole" measurement methods when speed and simplicity are needed or when other methods fail (exterior and interior walls)
Leak detection and documentation, available upon request, including
- using smoke tests, leak detection from the inside and outside
- in conjunction with thermography
Technical Specifications
Measurement range
- Standard: up to 10,000 m³/h and a 60 Pa pressure differential between indoors and outdoors
- Extended up to 30,000 m³/h and a pressure difference of 60 Pa between indoors and outdoors