Determination of the µ-value

Scope of Application

In the climate-controlled µ-value test chamber, the following parameters of a sample can be determined in a differential climate by measuring the mass flow rate:

  • Determination of the water vapor diffusion resistance coefficient µ
  • Determination of the water vapor diffusion flux density g
  • Determination of the water vapor diffusion-equivalent air layer thickness (sd)
  • Determination of sorption isotherms

Examples of Use

Technical Specifications

The test chamber consists of a vapor-tight, corrosion-resistant, and water-absorbing chamber designed to hold the samples. Its dimensions are: 470 mm × 370 mm × 1,100 mm. Under controlled, constant temperature and humidity conditions, the diffusion flux densities are determined in a steady state across various humidity ranges. The temperature stability is 0.5 K, and the humidity stability is within ±2%.